歡迎來到匠仁醫療設備有限公司網站!
1.顯示屏幕出現花屏、閃屏或黑屏等情況。 這種情況可能是由于內窺鏡顯示屏幕的連接線路不良或者內部電路出現問題,方法是檢查連接線路是否...
1. The display screen may appear as a splash screen, flashing screen, or black screen. This situation may be due to poor connection wiring of the endoscope display screen or internal circuit problems. The solution is to check if the connection wiring is
2.內窺鏡成像模糊或者顏色失真。 這種情況可能是由于內窺鏡鏡頭污垢過多或者光源出現問題,可以嘗試使用干凈的軟布清潔內窺鏡鏡頭,如果清潔后...
2. Endoscopic imaging is blurry or color distorted. This situation may be due to excessive dirt on the endoscope lens or problems with the light source. You can try using a clean soft cloth to clean the endoscope lens. If
3.內窺鏡無法伸縮或者彎曲。 這種情況可能是由于內窺鏡的機械結構出現故障,需要將內窺鏡送回售后服務中心或者的維修機構進行檢修和維修。
3. The endoscope cannot stretch or bend. This situation may be due to a malfunction in the mechanical structure of the endoscope, which requires the endoscope to be sent back to the after-sales service center or a professional repair organization for inspection and maintenance.
4.內窺鏡的電池不能正常充電或者電池壽命較短。 這種情況可能是由于內窺鏡電池老化或者內窺鏡充電線路不良導致的。 方法是更換新的電池或者檢查充電線路是否正常。
4. The battery of the endoscope cannot be charged normally or has a short battery life. This situation may be caused by aging of the endoscope battery or poor charging circuit of the endoscope. The solution is to replace the battery with a new one or check if the charging circuit is working properly.
5.鏡頭無法對焦或者對焦困難。 這種情況可能是由于鏡頭結構出現問題,或者是鏡頭與內窺鏡機身的連接處出現問題。 方法是檢查連接處是否松...
5. The lens cannot focus or has difficulty focusing. This situation may be due to problems with the lens structure or issues with the connection between the lens and the endoscope body. The solution is to check if the connection is loose
6.光源不亮或者亮度不足。 這種情況可能是由于光源燈泡損壞,或者是光源電路出現問題。 方法是更換新的燈泡或者將內窺鏡送回售后服務中心...
6. The light source is not bright or the brightness is insufficient. This situation may be due to a damaged light bulb or a problem with the light source circuit. The solution is to replace the light bulb with a new one or send the endoscope back to the after-sales service center
7.內窺鏡機身變形或者損壞。 這種情況可能是由于內窺鏡機身受到外力撞擊或者過度擠壓導致的。 方法是將內窺鏡送回售后服務中心或者的維修機構進行檢修和維修。
7. The endoscope body is deformed or damaged. This situation may be caused by external impact or excessive compression on the endoscope body. The solution is to send the endoscope back to the after-sales service center or a professional repair institution for inspection and maintenance.
8.內窺鏡機身進水或者受潮。 這種情況可能是由于使用環境潮濕或者不當使用導致的。 方法是將內窺鏡送回售后服務中心或者的維修機構進行檢修和維修。
8. The endoscope body is exposed to water or moisture. This situation may be caused by a humid environment or improper use. The solution is to send the endoscope back to the after-sales service center or a professional repair institution for inspection and maintenance.
9.內窺鏡機身過熱或者不工作。 這種情況可能是由于內窺鏡電路出現問題或者內部散熱不良導致的。 方法是將內窺鏡送回售后服務中心或者的維修機構進行檢修和維修
9. The endoscope body is overheated or not working. This situation may be caused by problems with the endoscope circuit or poor internal heat dissipation. The solution is to send the endoscope back to the after-sales service center or a professional repair institution for inspection and maintenance
我們專門為您提供內窺鏡設備維修服務,想要了解更多的資訊內容,歡迎訪問我們的網站:http://www.dibeisi.top我們會有更多的內容等您查看。
We specialize in providing maintenance services for endoscopic equipment. For more information, please visit our website: http://www.dibeisi.top We will have more content waiting for you to review.
樊經理:13153199508 李經理:13873135765
公司地址:山東省濟南市槐蔭區美里東路3000號德邁國際信息產業園6號樓101-2室 湖南省長沙市雨花區勞動東路820號恒大綠洲14棟2409室