在醫院各科室中,醫療用內窺鏡的使用非常嚴格,包括它的零部件使用,下面
內窺鏡設備維修公司為您講解下相關內容。
In all departments of the hospital, the use of medical endoscope is very strict, including the use of its components. The endoscope equipment maintenance company will explain the relevant contents for you.
室內儀器定位放置:
Indoor instrument positioning:
手術間的電源插座應為屋頂懸掛式,避免因工作人員走動碰脫電源插座而使電源線受干擾,保證手術的順利進行,同時也避免由于電壓不穩而造成儀器損壞。
The power socket in the operating room should be roof-mounted to avoid the interference of the power cord caused by the staff moving and touching the power socket, so as to ensure the smooth operation and avoid the damage of the instrument due to the unstable voltage.
監視器:
Monitor:
一般監視器在安裝時已經都是有相關技術人員進過測試并調整到了很好的顯示狀態,所以不建議使用者自行調試。如果監視器不顯示,請檢查插線板和電源線的連接,顯示器開關是否處于打開狀態、攝像系統是否處于打開狀態、攝像系統的輸出是否正確的連接到監視器的輸入端口。
Generally, the monitor has been tested and adjusted to a good display state by relevant technical personnel during installation, so it is not recommended that users debug by themselves. If the monitor does not display, check the connection of the patch panel and the power cord, whether the display switch is on, whether the camera system is on, and whether the output of the camera system is correctly connected to the input port of the monitor.
顏色失真后可將攝像系統的光學接口對準顏色比較鮮明的物體或圖片,通過監視器上的菜單進行對比度、飽和度、亮度的調節。避免強磁物體靠近監視器,定期作消磁保養,當磁化嚴重或消磁失效的時候,請聯系廠家技術人員。
After color distortion, the optical interface of the camera system can be aimed at objects or pictures with bright colors, and the contrast, saturation and brightness can be adjusted through the menu on the monitor. Avoid strong magnetic objects close to the monitor, and perform degaussing maintenance regularly. In case of serious magnetization or degaussing failure, please contact the manufacturer's technical personnel.
攝像系統和光源:
Camera system and light source:
雖說很多醫療內窺鏡聲明光學接口是防水的,但光學接口和連接線不建議,可用套套上,每次使用時套,這樣可以大大增加光學接口的使用壽命,如必須請用低溫熏蒸的方法。
Although many medical endoscopes declare that the optical interface is waterproof, it is not recommended to disinfect the optical interface and the connecting line. It can be put on the germ-proof sleeve and sterilize the germ-proof sleeve every time it is used, which can greatly increase the service life of the optical interface. If it is necessary to disinfect, please use the method of low temperature fumigation.
插口不能強插拔,要對準十二點的位置進行直插、直拔輕拿輕放,定期作白平衡校準。防止光學接口接觸液體,即使聲稱是防水的設備,所以不要將調焦頭及連線浸泡,如不甚接觸葡萄糖一類的液體請手術后立即用干布擦干凈光學接口表面液體。防止卡口結晶運動不靈活,如果出現異常請不要勉強使用。
The socket cannot be forcefully inserted and pulled out. It should be directly inserted and pulled out at the position of 12 o'clock, handled gently, and regularly calibrated for white balance. Prevent the optical interface from contacting with liquid, even if it is claimed to be waterproof equipment, so do not immerse and disinfect the focusing head and wiring. If it does not contact with liquid such as glucose, please wipe the liquid on the surface of the optical interface with a dry cloth immediately after the operation. Prevent inflexible movement of bayonet crystallization. If there is any abnormality, please do not force to use it.
光纜不可用浸泡方式或高溫高壓方法,如需請用低溫熏蒸或淡酒精擦拭表面的方法進行。使用者要細心記錄光源燈泡的使用時間,臨近使用壽命時準備備用燈泡。光源燈泡有使用壽命的限制,建議不使用時立即關閉光源。
The optical cable cannot be disinfected by immersion or high temperature and high pressure. If it needs to be disinfected, please use low temperature fumigation or light alcohol to wipe the surface. The user should carefully record the service time of the light source bulb and prepare the spare bulb when it is close to its service life. The light source bulb has a limited service life. It is recommended to turn off the light source immediately when it is not in use.
內窺鏡對使用環境的要求為室內環境以暗室環境為主,避免強光直射,手術開始關閉日光燈,用無影燈照明,術前室內的溫度保持在22℃~25℃、濕度50%左右、防酸、防堿、防蒸氣。避免強電、電磁場的干擾。更多事項就來我們網站
http://www.dibeisi.top咨詢了解!
The requirements for the use environment of the endoscope are that the indoor environment is mainly darkroom environment, avoiding direct sunlight, turning off the fluorescent lamp at the beginning of the operation, using shadowless lamp for lighting, and maintaining the indoor temperature at 22 ℃~25 ℃, humidity at about 50%, acid, alkali and vapor proof. Avoid interference of strong current and electromagnetic field. Come to our website for more matters http://www.dibeisi.top Consult and understand!