腹腔鏡設備是現代電子、光學、機械融為一體的高科技精細手術設備,在腹腔鏡手術操作中,操作器械繁多,構造精密,價錢昂貴,容易發作毛病和破損,因而須控制正確的腹腔鏡清洗和保養辦法。腹腔鏡是硬式內鏡,必需到達效果后才能使用。下面
內窺鏡設備維修的小編就帶大家一起來看一下吧!
Laparoscopic equipment is a modern electronic, optical, mechanical integration of high-tech fine surgical equipment, in laparoscopic surgery, operating instruments are various, precise structure, expensive, prone to defects and damage, so it is necessary to control the correct laparoscopic cleaning and maintenance methods. Laparoscopy is a rigid endoscope, which can only be used after reaching the sterilization effect. The following endoscopic equipment repair of the small series will take you to have a look!
到達效果的前提是清洗徹底。腹腔鏡運用后,清洗不到位,可致醫源性穿插感染,影響醫療質量和平安,內鏡器械清洗中潛在問題清洗不充沛、清洗流程落實不到位:腔鏡器械數量有限,供需矛盾突出,加上人員缺乏,沒有足夠的時間清洗,刷洗或義務心不強,無專人管理。
The premise of sterilization effect is thorough cleaning. After the use of laparoscopy, if the cleaning is not in place, it may cause iatrogenic interspersed infection and affect the medical quality and safety. The potential problems in the cleaning of endoscopic instruments are not sufficient, and the cleaning process is not implemented in place: the number of endoscopic instruments is limited, the contradiction between supply and demand is prominent, coupled with the lack of personnel, there is not enough time for cleaning, and there is no strong sense of obligation to brush or wash, and there is no special person to manage.
刷洗工具不理想:醫院不注重置辦專制刷洗工具,刷子尺寸大小不契合請求,刷洗工具量少,刷洗不徹底,清洗室設備不齊全:無水槍、氣槍、烤箱,無專置的超聲酰清洗機。
The washing tools are not ideal: the hospital does not pay attention to the purchase of authoritarian brushing tools, the size of the brush does not meet the requirements, the amount of brushing tools is small, the brushing is not complete, the cleaning room equipment is not complete: no water gun, air gun, oven, no special ultrasonic acyl cleaning machine.
器械拆卸不到位:局部部位拆卸未少化,未清洗到局部關節部位及內腔,手術時反吸的血污較難清洗潔凈,極易殘留污物和細菌,運用后器械疏忽用活動水初洗,直接用多酶清洗液浸泡影響清洗效果;或為節約多酶清洗液,未做到一人一換酶,重復運用,易形成二次感染。
Equipment disassembly is not in place: the local parts are not disassembled to a minimum, and the local joint parts and internal cavity are not cleaned. During operation, it is difficult to clean the bloodstain, which is easy to remain dirt and bacteria. After using the equipment, the equipment is not washed with active water and soaked with multi enzyme cleaning solution directly, which affects the cleaning effect; or in order to save the multi enzyme cleaning fluid, one person does not change the enzyme, and repeated use is easy to form Secondary infection.
The above is about the correct method of laparoscopic equipment cleaning, I believe you have mastered it, if you want to know more, welcome to click endoscopic equipment maintenance http://www.dibeisi.top Official website.